Tyco 4099-9004 | Call Points | Indoor | Detectoresymedidores
Detectores de Fuga de Gases y Flama, Analizadores, Dispositivos de Alarma y Gases de Calibracion

TYCO   4099-9004

TYCO 4099-9004

ALARM SIGNAL DEVICES / INDOOR
CALL POINTS

$67.52 Dls [2 Dias]
  • DESCRIPCION
  • CARACTERISTICAS
  • ESPECIFICACIONES
  • LITERATURA
Tyco Simplex 4099-9004 addressable manual station with communication module for IDNet or MAPNET II. LED indicator. Breakglass or push operation. Surface or Flush mounting. NEMA 1. Complies with ADA requirements. UL listed.

4099-9004   
67.52

Versión

   2 Dias  ]

Configuraciones Estandard tipicamente disponibles en 2 Dias:
4099-9004__    4099-9006__
11 Variants of base SKU
Features Individually addressable manual fire alarm stations with:
  • Power and data supplied by IDNet or MAPNET II addressable communications using a single wire pair
  • Operation that complies with ADA requirements
  • Visible LED indicator that flashes during communications and is on steady when the station has been activated
  • The NO GRIP Single Action Station and Retrofit Kit are available with a more easily operated pull lever for applications where anticipated users may find the standard station lever difficult to activate
  • Pull lever that protrudes when alarmed
  • Break-rod supplied (use is optional)
  • Models are available with single or double action (breakglass or push) operation
  • UL listed to Standard 38
  • NEMA 1 rated. See Addressable manual station product selection for more information.
Compatible with the following Simplex control panels:
  • Model Series 4007ES, 4008, 4010, 4010ES, 4100ES, 4100U, 4020, 4100, and 4120 fire alarm control panels equipped with either IDNet or MAPNET II communications
  • Model Series 2120 Communicating Device Transponders (CDTs) equipped with MAPNET II communications
Compact construction:
  • Electronics module enclosure minimizes dust infiltration
  • Allows mounting in standard electrical boxes
  • Screw terminals for wiring connections
Tamper resistant reset key lock, keyed same as Simplex fire alarm cabinets. Multiple mounting options:
  • Surface or semi-flush with standard boxes or matching Simplex boxes
  • Flush mount adapter kit
  • Adapters are available for retrofitting to commonly available existing boxes
Description

The Simplex addressable manual station combines the familiar Simplex manual station housing with a compact communication module that is easily installed to satisfy demanding applications. Its integral individual addressable module (IAM) constantly monitors status and communicates changes to the connected control panel through IDNet or MAPNET II communications wiring.

Operation

Activation of the 4099-9004 single action manual station requires a firm downward pull to activate the alarm switch. Completing the action breaks an internal plastic break-rod which is visible below the pull lever, use is optional. The use of a break-rod can be a deterrent to vandalism without interfering with the minimum pull requirements needed for easy activation. The pull lever latches into the alarm position and remains extended out of the housing to provide a visible indication.

Single Action NO GRIP Station 4099-9021. For applications such as California Building Code, Title 24, which requires "Controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist" the model 4099-9021 station provides a more easily operated pull lever compared to standard stations. Retrofit of existing stations is available using the 4099-9805 Retrofit kit.

Double Action Stations (Breakglass) require the operator to strike the front mounted hammer to break the glass and expose the recessed pull lever. The pull lever then operates as a single action station.

Double Action Stations (Push Type) require that a spring loaded interference plate, marked PUSH, be pushed back to access the pull lever of the single action station.

Station reset requires the use of a key to reset the manual station lever and deactivate the alarm switch. If you use the break-rod, you must replace it.

Station testing is performed by physical activation of the pull lever. You can also perform electrical testing by unlocking the station housing to activate the alarm switch.

Specification
Power and communicationsIDNet or MAPNET II communications, 1 address for each station
Address meansDIP switch, 8 position
Wire connectionsScrew terminal for in/out wiring, for 18 AWG to 14 AWG wire (0.82 mm to 2.08 mm )
UL listed temperature range32°F to 120°F (0°C to 49°C) intended for indoor operation
Humidity rangeUp to 93% RH at 100°F (38°C)
Housing colorRed with white raised lettering
MaterialHousing and pull lever are Lexan polycarbonate or equal
Pull lever colorWhite with red raised lettering
Housing dimensions5 in. H x 3 3/4 in. W x 1 in. D (127 mm x 95 mm x 25 mm)

 Solicitar Info/Cotizacion
 Descuento en Reventa y Vol
 Costo del Flete

Opciones B2B: #Order de Compra, uso de cuenta de envio propia y compra exenta de impuesto
Opciones de Pago: Tarjeta de Credito, Tarjeta de Credito por Telefono, PAYPAL, Transferencia, Deposito, Cheque y Orden de Pago

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

Aviso de Cookies

Esta tienda en línea utiliza cookies para recordar a los usuarios, permitir el pago y recopilar información agregada que nos permite analizar los patrones de tráfico en nuestro sitio (no se almacena información personal). Para más información puedes leer nuestra Política de Privacidad.