Detectores de Fuga de Gases, Analizadores, Dispositivos de Alarma y Gases de Calibracion
SKU# (2714)

BACHARACH  3015-5330

$6,560.10 Dls    Tiempo de Embarque: 3 Dias
 Solicitar Info/Cotizacion
 Costo del Flete
 Descuento por volumen



BACHARACH 3015-5330
  • General
  • Caracteristicas
  • Especs
  • Relacionados
  • Literatura

Kit Bacharach HGM-MZ+RD de Halógeno para MúltiplesZonas. Incluye detector de gasHGM-MZ para el monitoreo continuo de regrigerantes (CFC, HFC y HCFC) 0-10000 ppm y pantalla remota. Hasta 16 Zonas. Pantalla LCD, 4 contactos de alarma SPDT y interfaz RS-485. Entrada de 120-240 VAC, 50/60Hz. Salida opcional dual de 4-20mA. Aprobado por UL, CSA, EN y CE Mark. Extensa Biblioteca de gasesrefrigerantesincluida.

Parte# con Opciones:        3015-5330
Precio con Opciones:        6,560.10

Opciones:    

Zonas
(1) Zonas para Bacharach HGM MZ RD

  Tiempo de Embarque 3 Dias  ]

Ideal for Chillers, Grocery Stores, Mechanical Rooms Physical Plants, Refrigeration Racks, Walk-In Freezers

Features & Benefits
  • Proprietary infrared sensing technology virtually eliminates false alarms and extends sensor life
  • No calibration required
  • Low detection limits enable leaks to be found early reducing energy and refrigerant consumption
  • Fastest sampling rate with the longest sampling distance in the industry at 1,200 feet
  • Large Graphic LCD for easy set-up and real-time monitoring

Bacharach’s Multi-Zone Gas Leak Monitors offer superior performance, flexibility and functionality for low level continuous monitoring of refrigerant gases used in most commercial systems including: Chlorofluorocarbons (CFC), Hydrochlorofluorocarbons (HCFC), Hydrofluorocarbons (HFC), Ammonia (NH 3 ) and Carbon Dioxide (CO 2 ). These state-of-the-art fixed gas monitors lead the industry in performance, integration capabilities, initial cost and cost of ownership. Capable of detecting more than 38 refrigerant gases, the Multi-Zone system is compliant with ASHRAE standard 15-2007, is ETL Energy Saving Listed, meets California Code Regulations for Refrigerant Monitors and is EN 14624 and CE certified.

Critical Protection with Flexible Configuration

Bacharach Multi-Zone Monitors provide continuous detection of refrigerant gas levels in up to 16 separate test zones and can be fitted with an optional two channel 4-20 mA current loop board for connection to remote monitoring equipment. Multi-Zone monitors retain a log of previous readings that can be easily accessed for analysis. Four relay contacts are provided that can be programmed to trigger external alarm devices in the event of a system fault, or if a leak (small), spill (medium) or evacuation (large) level of gas is detected, while audible and visual front panel indicators show alarm and fault conditions. With only minor periodic maintenance, such as the occasional replacement of filters, and active diagnostics that continuously check the system for proper operation, Multi-Zone monitors help maintain your equipment efficiency, promote safety and protect the environment.

Multi-Zone Specifications
Product Type: The Multi-Zone Gas Leak Monitor is a multiple area monitoring system for low level continuous monitoring of refrigerant gases used in most commercial systems including: CFC, HCFC, HFC, Ammonia and Carbon Dioxide. System design supports compliance to the gas monitoring requirements of ANSI/BSR ASHRAE 15-2007.
Coverage: 4 Point Standard, Expandable to 16 Points in 4 Point Increments
Detector Type: Single-Pass, Non-Dispersive (NDIR)
Gas Library: CFC: R11, R12, R113, R114, R502, HFP
HFC: R404A (HP62), R407A, R407C (AC9000), R134A, R410A (AZ20), R507 (AZ50)
HCFC: R21, R22, R23, R123, R124, R227, R500, R503, R401A (MP39), R402A (HP80), R402 (HP81), R408A, R409A, R508B (SUVA95), R236FA, R125, R245FA, R422A, R422D, R427A
Halon: H1301, H2402, H1211
Other: FA188, FC72, N1230, HFO1234YF, R424A, R426A, R427A, R438A
Measuring Range: All gases 0 to 10,000 ppm
Accuracy: ±1 ppm ±10% of reading from 0-1,000 ppm (R11, R22, R13: ±10 ppm ±15% of reading 0-1,000 ppm)
Temperature Drift:: ±0.8% (R134A) of reading per Degrees C between purge cycles
Display Resolution: 1 ppm
Dimensions: 12.23” x 13.7” x 4.96” (31.0642 cm x 34.798 cm x 12.5984 cm)
Weight: 15 lbs (6.80kg)
User Interface: Front panel w/3 indicator lights: Green - Power On, Normal; Yellow - Fault; Yellow Flashing - System Fault; Red/Flashing - point has exceeded alarm set.
Communications: Full 2-way communication with MZ-RD display module or building management system via RS-485 Serial Interface. RS-232C Comm. Port Standard.
Alarms: Four SPDT alarm contacts are provided rated 2A at 250 VAC (Inductive), 5A at 250 VAC (Resistive). Three assigned to ppm level alarms. One assigned to system faults.
Conditioned Signal: Optional Dual 4-20 mA DC isolated outputs. Channel 1=zone area, Channel 2=ppm
System Noise: Less than 40dB at 10 Ft. (3m)
Response Time: 5 to 315 seconds – Depending on air line length and number of zones
Sampling Mode: Automatic or Manual (Hold)
Re-Zero: Every 5 minutes or on 0.5 Degree C internal temperature change
Monitoring Distance: 1,200 ft. max. (500 ft. for NH 3 ) for combined length of sample and exhaust tubing (each zone)
Power Safety Mode: Fully automatic system reset. All programmed parameters retained
Operating Temp: 32° to 122° F (0 to 50° C)
Ambient Humidity: 5% to 90% RH Non-condensing
Altitude Limit: 6,562 Ft. (2,000 m)
Power: 100 to 240 VAC, 50/60 Hz, 20 W
Approvals: UL 61010-1, CAN/CSA 22.2 No. 61010-1; EN61010-1, EN61326, EN14624; CE Mark

  • ACCESORIOS > BACHARACH
    3015-3430 Kit de Verificación de gas Bacharach R-22 ..

  • ACCESORIOS > BACHARACH
    3015-3437 Kit de Verificación de gas Bacharach R-134a ..

  • ACCESORIOS > BACHARACH
    3015-3438 Kit de Verificación de gas Bacharach R-123 ..

  • ACCESORIOS > BACHARACH
    3015-3850 Cilindro de Gas Bacharach 1031. 100 PPM R-22 ..

  • ACCESORIOS > BACHARACH
    3015-3851 Cilindro de Gas Bacharach 1031. 100 PPM R-134a ..

  • ACCESORIOS > BACHARACH
    3015-3852 Cilindro de Gas Bacharach 1031. 100 PPM R-123 ..

  • DETECTORES DE GAS (USO GENERAL) > REFRIGERANTE
    3015-5043 Detector de gas Bacharach HGM-MZ de Halógeno para MultiplesZonascon sensor infrarrojo (NDIR) para monitoreo continuo de regrigerantes (CFC, HFC y HCFC) 0-10000 ppm. Hasta 16 Zonas. Incluye pantalla LCD, 4 contactos de alarma SPDT y interfaz RS-485. Entrad ..

  • MONITORES > BACHARACH
    3015-5138 Monitor remoto Bacharach MZ-RD para MúltiplesZonascon acceso para diagnóstico, comunicación u control de Unidades Bacharach de zona múltiple. El MZ-RD puede conectarse con hasta 4 monitores, permitiendo la cobertura de hasta 64 zonas de muestreo. ..


Opciones B2B: #Order de Compra, uso de cuenta de envio propia y compra exenta de impuesto
Opciones de Pago: Tarjeta de Credito, Tarjeta de Credito por Telefono, PAYPAL, Transferencia, Deposito, Cheque y Orden de Pago

Checkout with Paypal

> REFRIGERANTE :    6 Articulos encontrados.
AT-2064-A-000-0
(2912)

INTEC  AT-2064-A-000-0

Transmisor de gas intec Controls Polygard AT-2000 V3 Analógico para refrigerantes (HCFC y HFC) 0-500 / 0-1000 / 0-2000 ppm (infrarrojo). 2 salidas de relé, 1 salida de 4-20mA y 1 salida analógica de 2-10V. Montado en la pared. NEMA 4X. Listado por UL Listed y certificado por CSA. Configuración de fábrica para R123, R125, R410a, R22, R134a, R404a o R407A.

Configurar

$1,053.00 Dls
GG-_R22-0500
(2969)

CALIBRATION TECHNOLOGIES  GG-R22-0500

Sensor infrarrojo CTI GasGuard para Refrigerante (R11, R22, R134a, R404a, R410a y R507a) (0-500 o 0-3000 ppm) para la detección de fugas de gas en Sistemas de refrigeración, áreas de procesamiento de alimentos, plantas de embotellamiento y otros. Sin falsas alarmas. Salida de 4-20 mA, fuente de alimentación de 24 VDC y Gabinete de policarbonato NEMA 4X.

Configurar

$1,092.00 Dls
IR-F9-R410a-1000-N1
(1545)

HONEYWELL  IR-F9-R410a-1000-N1

Detector de Gas Honeywell Analytics Manning IR-F9 con sensor infrarojo para Refrigerante R410a con salida de 4-20 mA. 24VDC. Gabinete NEMA-1.

Configurar

$1,163.48 Dls
IR-F9-R134a-1000-N1
(1540)

HONEYWELL  IR-F9-R134a-1000-N1

Detector de Gas Honeywell Analytics Manning IR-F9 con sensor infrarojo para Refrigerante R134a con salida de 4-20 mA. 24VDC. Gabinete NEMA-1.

Configurar

$1,163.48 Dls
3015-4200
(2709)

BACHARACH  3015-4200

Detector de gas Bacharach HGMSZ de Halógeno de Zona Simple con sensor infrarrojo (NDIR) para monitoreo continuo de regrigerantes (CFC, HFC y HCFC) 0-10000 ppm. Incluye fuente de poder, pantalla LCD y indicadoresLED. Salida de 4-20mA. Aprobado por UL, CSA, EN y CE Mark. Extensa Biblioteca de gasesrefrigerantesincluida.



$2,895.30 Dls
3015-5043
(2712)

BACHARACH  3015-5043

Detector de gas Bacharach HGM-MZ de Halógeno para MultiplesZonascon sensor infrarrojo (NDIR) para monitoreo continuo de regrigerantes (CFC, HFC y HCFC) 0-10000 ppm. Hasta 16 Zonas. Incluye pantalla LCD, 4 contactos de alarma SPDT y interfaz RS-485. Entrada de 120-240 VAC, 50/60Hz. Salida opcional dual de 4-20mA. Aprobado por UL, CSA, EN y CE Mark. Extensa Biblioteca de gasesrefrigerantesincluida.

Configurar

$5,695.20 Dls