Detectores de Fuga de Gases y Flama, Analizadores, Dispositivos de Alarma y Gases de Calibracion
BACHARACH 6300-1035
  • General
  • Caracteristicas
  • Especs
  • Literatura

Detector y Transmisor de gas Bacharach MGS150 con sensor electroquímico para Fluor (F2) 0-1ppm. SalidasAnalógicas seleccionables: 4-20mA, 0-5V, 0-10V, 1-5V o 2-10V. LED de alarma, zumbador y relé de alarma. Gabinente IP41. Aprobado por CE, IEC 61010, Exd, UL y CSA.

Solicitud de Información

Ideal for Commercial and Industrial Refrigeration, Food Storage and Food Processing Facilities, Supermarkets, Parking Garages, Wastewater Treatment Facilities, Hospitals and Universities.

Features and Benefits

  • Infrared, semiconductor and electrochemical sensor options to meet almost any gas detection need - at the most affordable cost.
  • User-selectable analog outputs: 4-20 mA, 0-5V, 0-10V, 1-5V, 2-10V featuring 12/24 VAC/VDC operation
  • Fast-response sensors detect leaks quickly, which protect personnel and minimize refrigerant gas usage and environmental impact.
  • Long-life semiconductor sensors for detection of all refrigerants, ammonia, halocarbons, combustible gases & VOCs
  • Robust design and remote sensor options allow units to be placed directly in areas where detection is needed.
  • Available in a variety of housings, including IP66 and duct mount, for placement in the toughest of environments.
Continuous Monitoring For Most Types of Gases

Bacharach’s MGS-150 Series Gas Transmitter is a feature-rich gas detection system with a wide range of sensor options to provide real-time monitoring of refrigerant, combustible, and toxic gases. It comes standard with user-selectable analog and digital outputs that can be set for 4-20 mA, 0-5V, 1-5V, 0-10V, or 2-10V; allowing them to connect directly to most BMS, SCADA or control systems. Alarm indicators include an onboard alarm LED and audible buzzer, in addition to an alarm relay for connection to external audible/visual alarms or a BMS system.

The product’s alarm threshold value is pre-set to factory defaults but is also field programmable. A variety of housing options are available (shown below), from standard IP41 enclosures to IP66 water resistant housings, which allow the MGS-150 Series gas sensors to be placed in the toughest of conditions.

MGS-150 Technical Specifications
Power Supply: 12/24 VAC/VDC operation
Power Consumption (12V): NDIR: 140 mA • SC: 160 mA • EC: 60 mA
Power Monitoring: Green LED
Visual Alarm: Red LED
Fault Monitoring: Red LED (On) • Green LED (Off)
Fault States: 0-1 V / 0-2 mA outputs
Analog Outputs: 4-20 mA, 0-5 V, 0-10 V, 1-5 V, 2-10 V
Relay Output (Volt-free): 1 relay, 1 amp 24 VAC/VDC
Alarm Delay: Selectable: 0, 1, 5 or 10 minutes
IP Rating: IP41 (standard) • IP66 (optional)
Dimensions & Weight
Standard IP41: 3.35”x5.59”x2.09” • 6.3oz.
86 x 142 x 53mm • 180g
IP66: 6.89”x6.5”x3.29” • 1lb. 6oz.
175 x 165 x 82mm • 629g
IP66 w/Splash: 6.89”x8.9”x3.29” • 1lb. 8.7oz.
175 x 225 x 82mm • 700g
IP66 / Remote: 6.89”x6.1”x3.29” • 1lb. 11oz.
175 x 155 x 82mm • 790g
IP66 / EXd: 6.89”x6.1”x3.29” • 2lb. 10oz.
175 x 155 x 82mm • 1185g
PRV / IP66 6.89”x6.1”x3.29” • 2lb. 0.3oz.
175 x 155 x 82mm • 916g
Airflow / Duct: 6.89”x4.9”x3.29” • 1lb. 4oz.
175 x 125 x 82mm • 578g
EXd (ATEX only): 5.12”x6.3”x3.54” • 9lb. 4oz.
130 x 160 x 90mm • 4200g
Approvals: CE • IEC 61010 (pending) • EXd • UL CSA (pending)
MGS-150 Electrochemical (EC) Sensor Information
Temperature Range: -4° F to 122° F (Stand. housing)
-20° C to 50° C (Stand. housing)
-40° F to 122° F (IP66 housing)
-40° C to 50° C (IP66 housing)
Humidity (non-condensing): 0 - 95%
Sensor Life: 2 - 5 years, typical
Time to Alarm (T50): 80 seconds, typical
Time to Alarm (T90): 220 seconds, typical
Recovery Time: 600 seconds, typical
Gases Detected
Ammonia (NH3) 0 - 100 ppm • 0 - 500 ppm • 0 - 1,000 ppm • 0 - 5,000 ppm
Carbon Monoxide (CO) 0 - 100 ppm • 0 - 500 ppm • 0 - 1,000 ppm
Chlorine (Cl2) 0 - 20 ppm
Chlorine Dioxide (ClO2) 0 - 1 ppm
Ethylene Oxide (C2H4O) 0 - 20 ppm
Ethylene (C2H4) 0 - 20 ppm • 0 - 1,000 ppm
Fluorine (F2) 0 - 1 ppm
Hydrazine (N2H2) 0 - 1 ppm
Saline - Hydride (SiH4) 0 - 5 ppm
Hydrogen (H2) 0 - 1,000 ppm
Hydrogen Chloride (HCl) 0 - 50 ppm
Hydrogen Cyanide (HCN) 0 - 50 ppm
Hydrogen Sulfide (H2S) 0 - 30 ppm • 0 - 200 ppm
Nitric Oxide (NO) 0 - 100 ppm • 0 - 1,000 ppm
Nitrogen Dioxide (NO2) 0 - 10 ppm
Oxygen (O2) 0 - 30% vol.
Ozone (O3) 0 - 2 ppm
Phosgene (COCl2) 0 - 1 ppm
Phosphine (PH3) 0 - 5 ppm
Sulfur Dioxide (SO2) 0 - 100 ppm

> FLUOR :    6 Articulos encontrados.
961-270026-001G
(6359)

DETCON  961-270026-001G

Detector de gas Detcon DM-100-F2 con sensor electroquímico para Fluór (F2) 0-1ppm con pantalla con alimentación de lazo (opcional). Salida de 4-100 mA. Incluye dispositivos electrónicos inteligentes, interfaz de operador no intrusiva y detector de fallas. Gabinete de acero inoxidable 316 (opcional). NPT 3/4". Intrínsecamente seguro (XP). Para Clase I, Div. 1, Grupos A, B, C y D.

GM/EC-03-25-01
(394)

GDS  GM/EC-03-25-01

Detector de Gas GDS GASMAX/EC para Flour (F2) con rango 0-1 ppm, con cabeza sensora local de acero inoxidable (no XP). Tiene Transmisor de 2 hilosa 4-20 mA.

Configurar

$1,700.00 Dls
967-272790-001
(6083)

DETCON  967-272790-001

Detector de gas electroquímico inteligente Detector de gas Detcon DM-700-F2 para Fluor (F2) 0-1 ppm con pantalla LED. Salidas de 4-20mA y Modbus RS-485. Gabinete de acero inoxidable 316. A prueba de agua, corrosión, vibraciones y explosiones. NEMA 4X. IP66. Clase I, Div. 1, Grupos B, C y D. Aprobado por CSA y ATEX.

GMII-03-025-01/00-000-00/0-0
(400)

GDS  GMII-03-025-01/00-000-00/0-0

Detector de Gas GASMAX II con cabeza sensora de acero inoxidable configurado para Fluor (F2) con rango 0-1 ppm. Transmisor de salida de 4-20mA. Trae como opción tarjeta de relés de alarma (3x 5A SPDT) y ModbusRS-485.

Configurar

$1,885.00 Dls
GMCX-03-25-01/00-00-00/0
(3299)

GDS  GMCX-03-25-01/00-00-00/0

Detector de gas GDS GASMAX CX de 3 hilos con cabeza sensora local de acero inoxidable configurado para Flúor (F2) con rango de 0-1ppm, pantalla a color QVGA TFT, salida de 4-20 mA, puerto Ethernet ModbusTCP RJ-45 con servidor web. Tablero de relés de alarma (4x 5A SPDT) y RTU RS-485 Modbusopcionales. Certificación CSA para Clase I, Div 1, Grupos B, C, D.

Configurar

$2,360.00 Dls
GM/TX/03-25-01/00-00-00/1-0900
(3435)

GDS  GM/TX/03-25-01/00-00-00/1-0900

Monitor de gas autónomo GDS GASMAX TX inalámbrico con cabeza sensora de acero inoxidable (no-XP) y sensor integrado configurado para Flúor (F2) con rango 0-1 ppm. Alimentado por batería. Modem integrado de 900 MHz o 2,4 GHz. Pantalla LCD y gabinete de aluminio. Aprobado por FCC e IC.

Configurar

$2,645.00 Dls