ESP SAFETY 100-0009-01
  • General
  • Detalles
  • Especs
  • Literatura

Controlador Multicanal ESP Safety UPes para el monitoreo y la detección de concentraciones de gase incendios. Sistema de control autónomo e independiente. Alarmasvisuales (LED) y sonoras. Incluye fuente de alimentación y 3 relés de alarma. Hasta 16480 canales analógicoso digitales. Compatible con PLC y SCADA. Aprobado por ABsy IECEx.

Parte# con Opciones:        100-0009-01
Precio con Opciones:        2,310.00

Opciones:    

Voltaje
(1) Voltaje para ESP Safety UPES

  Tiempo de Embarque 7 Dias  ]

ESP Safety’s Model UPES Multi-Channel Controller offers maximum flexibility to users as a standalone, independent control system that can also be interfaced to a PLC or DCS system. This advanced microprocessor-based monitoring system is compatible with all flame-detection and gas-sensor products offered by ESP Safety. Utilizing the analog outputs, 16 of ESP's detectors and sensors can operate in any combination. Utilizing the digital outputs, 480 of ESP's detectors and sensors can operate in any combination.

The UPES can be used at any facility for monitoring and detecting gas concentrations and flame and fire conditions. After being programmed with the desired thresholds, the UPES system will transmit light (LED) and sound alarms as well as signals to responding devices, such as warning systems, automatic sprinkler systems, ventilation systems, and emergency shutdown controls.

The UPES is built on a standardized housing 3Ux19 inches (482x266x132 mm) based on a highway-module concept. The UPES contains the power supply module and the controller module. It has internal rack space capable of holding eight channel cards for up to 16 analog or 480 digital signaling devices. The UPES control panel can display up to three separate alarm levels per signaling device.

Applications
  • Drilling and production platforms
  • Shipping tankers, freighters, and other vessels
  • Fuel loading facilities
  • Refineries, bulk terminals, and tank farms
  • LNG/LPG processing and storage facilities
  • Compressor stations and pipeline facilities
  • Petrochemical, paint, and fertilizer plants
  • Power plants and gas turbine facilities
  • Transportation facilities (airports and subways)
  • Oil and gas fired boilers / furnaces
  • Environmental regulation monitoring
Features and benefits
  • Maximum number of data channels: 1-16 analog or 1-480 digital channels offer broad gas-sensor coverage
  • Configurable for permanent or periodic indication
  • Three (3) programmable alarm relays, providing broad notification capability
  • Digital (when connected to an RS-485 interface), analog and relay outputs provide reliable status information across a range of communication formats
  • Modular measurement unit (3Ux19”) is compatible with industry standard size rack or standalone installation
  • Integrated two (2) line LED display for gas concentration
  • High maximum lengths of communication line for long-distance notifications: via 4-20 mA analog, up to 3937 feet (1200m); via RS-485, up to 16400 feet (5000m)
  • Compatible with PLC and SCADA
  • High-level audible alert

The network illustrated below, consisting of a UPES Multi-Channel Controller, SGOES and SSS-903 Gas Detectors, has the capacity to monitor potentially hazardous areas in proximity to oil and gas transit stations, gas and oil trunk pipelines, oil and gas storage tank farms, loading racks and similar facilities. When a lower explosive level (LEL) of gas presence (measured as a percent) has reached a preconfigured value, the UPES sounds an audible alert and sends alert signals to the control room monitoring devices while alerting operators. In addition, the UPES can send alert signals to facility level protection systems to initiate responses. These can include activating emergency facility shutdown, and automated ventilation system response.

Specifications
Electrical Characteristics
Voltage110V (±10V), 60Hz (±1Hz) Frequency / 24VDC from 18 to 32 VDC
OutputsRS-485 Modbus RTU compatible with PLC’s, SCADA, & DCS systems
4-20 mA analog output
Relays (dry contact) with programmable alarm level
One relay for fault condition
Operating Temperature-40°F to +158°F
(-40°C to +70°C)
HumidityUp to 95%, non-condensing (withstands up to 100% RH for short periods)
Mechanical Characteristics
Height5.19” (132mm)
Width19” (483 mm)
Depth9.3” (266 mm)
Weight37.47lbs (17.0kg)
Front Panel Indicators
3 color LED digital indicators
4 alarm LED indicators:
Green - Normal
One red - Low alarm
Two red - Auxiliary alarm
Three red - High alarm
Yellow - Fault


Opciones B2B: #Order de Compra, uso de cuenta de envio propia y compra exenta de impuesto
Opciones de Pago: Tarjeta de Credito, Tarjeta de Credito por Telefono, PAYPAL, Transferencia, Deposito, Cheque y Orden de Pago

Checkout with Paypal

> 16 CANALES :    4 Articulos encontrados.
MGC2-16-2000
(3539)

INTEC  MGC2-16-2000

Detector de gas multipunto y Sistema de Control Intec Controls Polygard MGC2-16 para la detección de gases, temperatura y humedad. Montado en la pared. 16 entradasanalógicas de 4-20 mA, 4 entradas digitales, 8 salidasanalógicas4-20 mA y 20 salidas de relé. Pantalla LCD. 120 VAC. Gabinete NEMA 4X. IP65. Listado por UL.

Configurar

$2,391.00 Dls
TPPLBDWA2NNNNNN-TPPLEDWA2NNNNNN
(5827)

HONEYWELL  TPPLBDWA2NNNNNN-TPPLEDWA2NNNNNN

Controlador de alarma Honeywell Touchpoint Plus con montaje de pared para 16 canales (incluye unidad de expansión). A prueba de polvo y a prueba de agua. Gabinete ABS de Policarbonato (NEMA 4X). Incluye una interfaz de pantalla táctil, sonda integrada, 3 salidas de alarma, registro de datos en tarjeta SD, reinicio remoto y entradas inhibidas. Alimentación AC o DC. Hasta 24 salidas de relé y 8 mA. IP65. Aprobado por UL y CSA (Clase I Div 2).

Configurar

$3,385.80 Dls
5700-1600
(2925)

BACHARACH  5700-1600

Controlador de Alarma Bacharach GDA-1600 de dieciséiscanales para monitorear hasta dieciséismonitores con entradas de 4-20mA. Pantalla LCD para verificar tipo de gas, concentración, gráficos de barrasy tendencias. Tresniveles de alarma ajustables. Salidas de relé. Incluye reloj de tiempo real y calendario. PuertosRS-485 y Ethernet disponibles. NEMA 4X. IP 66. Certificaciones: CSA / UL Div 2.

C1/SM/0000/000000/00000
(1641)

GDS  C1/SM/0000/000000/00000

Controlador de Alarma GDsC1 Multipunto con 8 o 16 canales para aplicaciones de alarma y monitoreo. Puede configurarse con detectoresinalámbricos gasMAX. 5 RelésSPDT estándar y hasta 48 relésdiscretos. 1 o 2 tableros de 8 canales con salidasanalógicas de 4-20mA (opcional). Opera con 10-30VDC o 110/220V 50/60Hz AC. CertificacionesDisponibles: CSA y UL. Incluye Modbusesclavo RTU RS-485 para enviar información a PC, PLC o DCS.

Configurar

$4,350.00 Dls