Tyco Simplex 4098-9401 Electronic Heat Detector for Two-Wire Direct Connect with fixed temperature operation. Thermistor based. Non-Addressable Initiation. Ceiling or wall mounting. LED alarm. UL, CSFM Listed and FM Approved.

4098-9401   
Favor de solicitar precio via Email   

Versión

   4 Semanas  ]
Features Accurate thermal detection for protection of property** UL listed to Standard 521 Fixed temperature operation is suitable for most applications:
  • Thermistor based design is inherently rate compensated due to minimal thermal lag
  • Available for 135° F (57° C) or 200° F (93° C)
  • UL spacing distance is 60 ft
Available with rate-of-rise temperature detection:
  • Dual thermistor rate-of-rise operation
  • For use where anticipated ambient temperature changes are less than 6° F/minute
  • UL spacing distance is 70 ft
Epoxy encapsulated electronic design provides:
  • Operation for ceiling or wall mounting
  • Easily tested, self-restoring operation with repeatable accuracy
  • Alarm indicating LED located on detector
  • Current limited alarm that is compatible with two-wire initiating device circuits (IDCs)
Direct connecting design:
  • Wiring attaches directly to detector terminals
  • Detector mounts onto mechanical adapter plate (supplied)

Accurate Electronic Design. Simplex electronic heat detectors use a fast response, thermistor based design to provide temperature sensing that quickly, accurately, and consistently identifies when fixed temperatures are exceeded. The fixed temperature sensing thermistor readily tracks the local ambient temperature. This eliminates the time required to melt a lead pellet or heat a bimetallic element as occurs in mechanical heat detector designs and provides the required heat detection for most applications.

Rate-of-rise detection is determined by comparing two thermistor responses. By combining accurate thermistors with proper physical placement, this patented rate-of-rise detection design achieves a high level of performance not normally available with mechanical detection.

Applications Reference

Heat detectors are used where property protection is desired and where life safety protection is not required or is performed by other equipment. Typical heat detector applications are satisfied by use of these fixed temperature electronic detectors.

The addition of rate-of-rise operation provides two forms of heat detection for use where temperature fluctuations are controlled and are less than 6° F/min (3.33° C/min). Where temperatures may fluctuate more quickly, use fixed temperature detection.

Fixed Temperature Guidelines

135° F (57° C) fixed temperature detectors are for normal temperatures that do not exceed 100° F (38° C).

200° F (93° C) fixed temperature detectors are for normal temperatures that exceed 100° F (38° C) but are less than 150° F (66° C).

Alarm Indicating LED Operation

The heat detector LED turns ON continuously when in alarm. During normal conditions the LED is OFF.

Specifications
Voltage Range 15 to 32 VDC, filtered DC with 30% maximum ripple
Standby Current 80 A nominal
Alarm Current Up to 100 mA maximum, exact current is determined by alarm current limiting of connected IDC
Rate-of-Rise Operation Meets FM requirements for operation between 15° and 25° F/min (8.33° and 13.88° C/min)
Humidity Range 10% to 95% RH, not intended for outdoor applications
Storage Temperature 0° to 140° F (-18° C to 60° C)
Color Off-white
Ambient Temperature Operating Range
135° F Models 32° to 100° F (0° to 38° C)
200° F Models 32° to 150° F (0° to 68° C)

 Solicitar Info/Cotizacion
 Descuento en Reventa y Vol
 Costo del Flete

Opciones B2B: #Order de Compra, uso de cuenta de envio propia y compra exenta de impuesto
Opciones de Pago: Tarjeta de Credito, Tarjeta de Credito por Telefono, PAYPAL, Transferencia, Deposito, Cheque y Orden de Pago

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> INTELLIGENT :    4 Articulos encontrados.
4098-9733
(6852)

SIMPLEX TYCO  4098-9733

Tyco Simplex 4098-9733 TrueAlarm Analog Heat Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

4098-9612
(6854)

SIMPLEX TYCO  4098-9612

Simplex 4098-9612 Electronic Heat Detector for Two-Wire Direct Connect with fixed temperature operation. 15 to 32 VDC. Thermistor based. Non-Addressable Initiation. Ceiling or wall mounting. LED alarm. UL, CSFM Listed and FM Approved.

4098-9714
(6845)

SIMPLEX TYCO  4098-9714

Tyco Simplex 4098-9714 TrueAlarm Analog SSD Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

4098-9754
(6847)

SIMPLEX TYCO  4098-9754

Tyco Simplex 4098-9754 TrueAlarm Multi-Point Analog Photoelectric and Thermistor Sensor for Early Fire Detection (smoke and thermal activity). IDNet communication. Ceiling or wall mounting. UL, ULC, CSFM and FM Approved.

Aviso de Cookies

Esta tienda en línea utiliza cookies para recordar a los usuarios, permitir el pago y recopilar información agregada que nos permite analizar los patrones de tráfico en nuestro sitio (no se almacena información personal). Para más información puedes leer nuestra Política de Privacidad.