Ams A001159 | Oxigeno+co | Sondas | Detectoresymedidores
Detectores de Fuga de Gases y Flama, Analizadores, Dispositivos de Alarma y Gases de Calibracion

AMS   A001159

AMS A001159
  • DESCRIPCION
  • CARACTERISTICAS
  • ESPECIFICACIONES
  • LITERATURA
Sonda de gas AMS 3211-1600 de alta temperatura con sensor de dióxido de circón para la medición de Oxígeno (O2) y Monóxido de Carbono (COe). Tubo de Ceramica o Kanthal. IP65. Temperatura máxima: 1100 °C.

A001159
Favor de solicitar precio via Email   

Unidad neumática
GFC Housing with window with built-in: Pressure reduction for reference air, Flowmeter with needle valve for reference air / cal. Gas, valves for manual actuation between the gases
Unidad neumática
GFC Housing with window with built-in: Pressure reduction for reference air, Flowmeter with needle valve for reference air / cal. Gas, valves for manual actuation between the gases

   4 Semanas  ]


The Application:

Complex combustion systems and processes require besides a fast In-Situ O2- measurement to control the combustion, a quality measurement to adjust the combustion system at a level which avoids the generation of CO. The control level around the point of CO generation is the optimum of the combustion. AMS offers for this application the COe In-Line Flue gas probe AMS 3211-1600 with a dual sensor which allows the measurement of O2 and unburnt Hydrocarbons. The unburnt Hydrocarbons are measured as CO equivalent (COe). Due to the fast response of the dual sensor the plant control can make use of the additional control value COe. The COe In-Line Flue gas probe AMS 3211-1600 can be operated with the Transmitter AMS 3220. The Transmitters is available as Twin- Version to supply separate signals for O2 and COe.

The Measuring principle:

The Sensor of the COe In-Line Flue gas probe AMS 3211-1600 is made of a electrochemical solid electrolyte sensor of partially stabilised Zircon dioxide ceramic. The sensor has three electrodes:

  • O2-sensitive Platinum electrode
  • CO / H2-sensitive electrode made of Platinum / Precious metal alloy
  • Platinum reference electrode

The measurement of COe with the COe In-Line Flue gas probe AMS 3211-1600 is not a CO measurement in the classical sense. The Flue gas probe AMS 3211-1600 measures in-situ the concentration of the sum of all combustible (oxidising) flue gas components such as CO and H2. The result of the measurement is displayed as COe. In applications with a known fuel at a constant composition the true CO concentration can be determined within limits. The COe In-Line Flue gas probe AMS 3211-1600 can be used for the measurement of O2 and Coe in Natural gas, Fuel Oil # 4, Lignite and Hard coal. The measuring range of the component COe is 1000 PPMv. For a quality measurement this range is quite sufficient, since the main purpose of the measurement is to avoid the generation of Carbon Monoxide. Due to the physical dimensions the sensor for measurement of O2 and COe can also be utilised with all other flue gas probes of AMS.

The Measuring system:

The High temperature Flue gas probe AMS 3211-1600 can be operated with the Transmitter AMS 3220 and a Pneumatic unit. The Pneumatic unit is fitted with all necessary regulation and control instruments for the high-pressure air supply for the pneumatic pump. The power supply of the Flue gas probe and the Transmitter is also installed in the Pneumatic unit. The flue gas probe, the Transmitter and the Pneumatic unit are manufactured according to the protection class IP 65 for General Applications. Since all AMS Flue gas probes are manufactured according to customer specification, the selection of the probe material as well as dimensions and sizes can be made fitting to any application. Optional the High temperature Flue gas probe AMS 3211-1600 can be equipped with time controlled back purge for high dust applications and with Auto-calibration for the automatic, time controlled calibration. To replace an already existing continuous oxygen measuring system the High temperature Flue gas probe AMS 3211-1600 can be fitted with all flange sizes both in DIN and ANSI dimensions. To calibrate the COe In-Line Flue gas probe AMS 3211-1600 both components O2 and CO have to be verified against a certified standard gas.

AMS 3211-1600
Measuring principle O2-COe-Sensor
Application Residual oxygen in flue gas
Construction ZrO2 sensor installed in the tip of the probe with stainless steel sintermetalfilter screwed on
Flue gas temp., max. 1100 °C
Dust content (flue gas) max. 5 Gram / Nm3
Flue gas velocity < 20 m/s
Time for pre-heating ~ 10 Minutes
T90-Time < 20 Seconds
Reaction time < 5 Seconds
Probe length 150 – 1000 mm
Connecting flanges DN 80 PN 16, DN 100 PN 16
Material Ceramics, Kanthal
Installation in the stack straight down
Protection IP 65
Reference air supply by separate pneumatic unit
Calibration gas supply by separate pneumatic unit
Weight ca. 6,5 kg
Accessories Transmitter: AMS 3220 in housing IP 65
Transmitter in twin-configuration
Pneumatic unit: GRP housing, Dimensions: 800 x 600 x 300 mm. Back-purge, Auto-calibration

 Solicitar Info/Cotizacion
 Descuento en Reventa y Vol
 Costo del Flete

Opciones B2B: #Order de Compra, uso de cuenta de envio propia y compra exenta de impuesto
Opciones de Pago: Tarjeta de Credito, Tarjeta de Credito por Telefono, PAYPAL, Transferencia, Deposito, Cheque y Orden de Pago

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESORIOS - RELACIONADOS - CONSUMIBLES :    1 Articulos encontrados.
A000154
(2774)

AMS  A000154

Transmisor y Analizador AMS 5200 CEMspara el control, la vigilancia y el suministro de Sondas de gasAMspara Oxígeno (O2) 0-25% vol y COe. Interfaz serial RS232. Salida de 4-20mA. 2 relés de alarma y 1 relé de estado. Gabinete IP65. Unidad neumática y gabinete Ex-d opcional para uso en zonasEx 1 ó 2. Sondascompatibles: AMS 3211-000 / 500 / 600 / 700 / 860 Ex. 110/240 VAC 50 o 60 Hz o 24 VDC.

> OXIGENO+CO :    1 Articulos encontrados.
A002410
(2918)

AMS  A002410

Sonda de gas AMS 3211-1500 en línea con sensor de dióxido de circón para la medición de Oxígeno (O2) y Monóxido de Carbono (COe). Tubo de acero inoxidable. IP65. Temperatura máxima: 400 °C.

Aviso de Cookies

Esta tienda en línea utiliza cookies para recordar a los usuarios, permitir el pago y recopilar información agregada que nos permite analizar los patrones de tráfico en nuestro sitio (no se almacena información personal). Para más información puedes leer nuestra Política de Privacidad.