Detector de Flama SPECTREX SharpEye 20/20MI Mini Triple IR (IR3) para incendios de gasolina, n-heptano, diesel, jp5, queroseno, alcohol, IPA, Metanol, metano, propano, polipropileno y papel. De bajo costo, gabinete de acero inoxidable, compacto y ligero. Alta resistencia a entornoshostiles, inmune a falsas alarmasy diseñado para aplicaciones de exterior o interior. 2 relés (alarma y falla), salida analógica de 0-20mA (sumidero o fuente). Built-In-Test (BIT) automático y manual. Compatible con RS-485 Modbus. Aprobado por ATEX Ex, FM, GOST R y GOST K.

20/20MI-11-S-F
2,942.62

Rango
Conección
Aprobación
Montaje de Inclinción
Escudo de Aire
Rain Shield

   4 Semanas  ]


The 20/20M Mini Series Flame Detectors are high performance, unique IR3 and UV/IR flame detectors featuring lower cost, lower power, and more compact structures. The mini detectors are highly resistant to harsh environments, immune to false alarms and are designed for use in OUTDOOR or INDOOR applications. The IR3 model is also available as intrinsically safe (I.S.) approved format.

The detectors’ small size, low cost and low power allow easy installation in small or congested areas where Ex hazardous area approvals are not a prime requirement. Both models are packaged in rugged, stainless steel enclosures that are less than 50% of the size of our standard explosion-proof detectors and weigh only 2.5 lbs (1.2 kg).

Features
  • Immune to False Alarms
  • Large Field of View (100° horizontal/vertical)
  • Low Power Consumption
  • High-Speed Response
  • Standard 4-Wire Connection
  • 4-20mA Sink or Source (3-4 wires) Configuration
  • RS-485 Modbus Compatible
  • Automatic and Manual Built-In-Test (BIT)
  • User-Programmable Function Configurable via software from a PC or handheld device
  • MTBF Minimum 100,000 Hours
  • 3 Year Warranty
Main Applications Aircraft Hangars

Leaking fuel is the main danger in aircraft hangars, easily causing fires and potentially harming personnel, equipment and facilities. The SharpEye Mini Optical Flame Detectors allow military and commercial requirements for reliable fire protection to be met. Due to the 100o cone of vision, there is wider coverage of the protected area. The area around the walls of the hangar where the detectors are mounted does not require EX proof so the 20/20MI non EX is suitable.

Off Road Heavy Duty Vehicle

Large mining vehicles are vulnerable to catastrophic fires particularly in engine compartments, as have been experienced in recent times. It is vitally important that fire protection capabilities are up to date with the latest technologies. The high-speed short-range version of 20/20MI-3 (up to 10 ft) is ideal to protect the large engine compartment of the vehicles, and is used in coal, metals and minerals mining.

Office Areas and Atrium Areas

While an atrium space has many merits, there is a danger that it could become a building’s weakness in fire protection, potentially allowing a fire to rapidly spread. The 20/20M Mini’s fast detection identifies a fire in its earliest stages, facilitating suppression. Modern hospitals feature large atria and open space areas. Due to the difficulty or impossibility of moving patients in an emergency, hospitals must follow a defend and protect in place policy rather than conventional evacuation. Hospital fire protection and evacuation requirements are therefore highly complex and the SharpEye Mini Optical Flame Detector is responsible for meeting them with its low cost and supreme reliability.

Waste Handling

Recycling reduces the quantities of materials deposited in the world’s landfill sites and saves natural resources, but must be coupled with appropriate fire safety measures. Unique risks are posed at recycling and waste handling operations, such as disposal and recycling of combustible materials. The 20/20M Mini Flame Detector is a successful choice to solve these issues, and has the additional benefit of low cost and low energy requirement. Recently, a recycling and waste handling plant in the Netherlands installed 84 SharpEye Optical Flame Detectors model 20/20MI to detect fire in the various deluge zones.

Unmanned Gas Stations

Modern automobile fueling areas are designed with high-speed self-service pumps, enabling customers to fuel their vehicles fast, but more susceptible to fire. Risks can include customers forgetting to return the nozzle, burning cigarettes, running engines, sparks and other heat sources, whereby flammable liquids can be easily ignited. The 20/20ML was designed to prevent any such hazards from spreading, combining UV and IR sensors to detect hydrocarbon- based fuel and gas fires, hydroxyl and hydrogen fires, as well as metal and inorganic fires.

Marine Vessels Engine Rooms

The engine room on a marine vessel is where the machinery of a ship is located. Fuel or oil spills from the machinery are a fire risk factor, alongside petrochemicals used for the cleaning and servicing of the machinery. The fuel, oil and petrochemicals are flammable and can easily ignite. Therefore, Spectrex Optical Flame Detectors are required to identify a fire and subsequently activate the installed fire suppression system. Spectrex 20/20M Mini Optical Flame Detectors are suitable for both commercial and military vessels.

Alongside the above-mentioned applications, the 20/20M Mini Series is specifically suited to the following applications:

  • Automotive parts manufacturing
  • Burners, boilers, and heaters
  • Car parking towers and garages
  • Chemical industry
  • Nuclear power plants
  • Power generation – pumps, generators and unmanned stations
  • Recreational and sports arenas (facilities)
  • Storage areas

20/20MI GENERAL SPECIFICATIONS
20/20MI-1 20/20MI-3
Spectral ResponseTriple Spectrum
Detection Range
(Highest Sensitivity Setting for 1ft2 (0.1m2) pan fire)
Fuel ft (m)
Gasoline 133 (40) 33 (10)
n-Heptane 133 (40) 33 (10)
Diesel Fuel 90 (27) 23.1 (7)
JP5 100 (30) 23.1 (7)
Kerosene 100 (30) 23.1 (7)
Alcohol (Ethanol) 100 (30) 24.8 (7.5)
IPA (Isopropyl Alcohol) 100 (30) 24.8 (7.5)
Methanol 100 (30) 24.8 (7.5)
Methane* 40 (12) 10 (3)
LPG (Propane)* 40 (12) 10 (3)
Polypropylene Pellets 16 (5) 6 (2)
Office Paper 50 (15) 13 (4)
*20" (0.5m) long 8" (0.2m) width plume fire
Response Time Typically 5 seconds.
Adjustable Time Delay Up to 30 seconds
Sensitivity Ranges4 Sensitivity Ranges for 1 ft2 (0.1m2) gasoline pan fire: 33 ft (10m)–133 ft (40m) 4 Sensitivity Ranges for 1 ft2 (0.1m2) gasoline pan fire: 7.5 ft (2.5m)–33 ft (10m)
Field of View Horizontal 100º; Vertical 100º
Built-in-TestManual and Automatic BIT
Temperature RangeOperating: -40°F (-40°C) to 160°F (70°C)
Storage: -65°F (-55°C) to 185°F (85°C)
HumidityUp to 95%
ELECTRICAL SPECIFICATIONS
Power SupplyOperating Voltage: 18-32 VDC
Power ConsumptionMax. 25 mA in stand-by
Max. 50 mA in alarm
Electrical Connection12 wires 6 ft (2m) cable (for junction box connection)
Optional: 12- wires electrical connector (the suitable connector will be supplied)
Electrical Input ProtectionAccording to MIL-STD-1275B
Electromagnetic CompatibilityEMI/RFI protected CE Marked
OUTPUTS
RelaysAlarm and Fault
SPST volt-free contact rates 2A at 30 VDC or 0.5A at 250 VAC Fault relay normally closed, Alarm Relay normally open
* The Relays do not apply to 20/20MI EX approved version
4-20mA (Source configuration) Sink (source option) configuration
Fault: 0 +0.5mA
BIT Fault: 2mA ± 10%
Normal: 5mA ± 10%
Warning: 10mA ± 5%
Alarm: 15mA ± 5%
Resistance Loop: 100-600 Ω
RS-485The detector is equipped with an RS-485 communication link that can be used in installation with computerized controllers. The RS-485 is Modbus compatible.
MECHANICAL SPECIFICATIONS
Dimensions4" x 4" x 2.5" (100 x 100 x 62 mm)
WeightSt.St 316L 2.5lb (1.2 kg)
Tilt Mount 0.8lb (0.37 kg)
Enclosure Stainless Steel 316L with electro polish finish
Environmental standardsMeets MIL-STD-810C for humidity, Salt & Fog, Vibration, Mechanical Shock, High Temp, Low Temp
Water and DustIP66 and IP67 per EN60529
NEMA 250 6P
APPROVALS
Hazardous Area Ex Approvals
ATEX** 04ATEX2010
EX II 1 GD, EExia IIC T5 (60°C), T4 (85°C)
Zener barriers (not included) are required to achieve the stated approval
** The Relays do not apply to 20/20MI EX approved version
Functional Approvals
FM Project ID 3020071 Project ID 3013906
VdS (EN54-10) G207073 ...
CPD Certificate of Conformity 0786-CPD-20916 ...
GOST R POCC US.HO06.B00103
Other Approvals
DNV A-12318
ABS Project No. 1627964
GOST K KZ.7500507.01.01.00029
Export Info
Fabricado enIsrael
Codigo Arancelario90318099

 Solicitar Info/Cotizacion
 Descuento en Reventa y Vol
 Costo del Flete

Opciones B2B: #Order de Compra, uso de cuenta de envio propia y compra exenta de impuesto
Opciones de Pago: Tarjeta de Credito, Tarjeta de Credito por Telefono, PAYPAL, Transferencia, Deposito, Cheque y Orden de Pago

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESORIOS - RELACIONADOS - CONSUMIBLES :    3 Articulos encontrados.
(3010)

SPECTREX  20/20-005

Soporte inclinable para detectores de flama SPECTREX 20/20MI



$153.35 Dls
794079-5
(3149)

SPECTREX  794079-5

Kit RS485 USB con convertidor RS485/232. Se utiliza con el software Spectrex Host y permite al usuario conectarse a cualquier computador disponible para reconfigurar ajusteso realizar diagnósticosen todos los detectores de flama 40/40 y 20/20.

Configurar

$464.44 Dls
FS-1100
(358)

SPECTREX  FS-1100

Simulador de flama SPECTREX SharpEye de largo alcance para los detectores de flama SPECTREX SharpEye Triple IR. Es la única manera de ejecutar pruebasfuncionalescompletasen susdetectoresSharpEye. Tiene certificación ATEX y Cenelec.



$5,929.05 Dls
> TRIPLE IR :    5 Articulos encontrados.
100-0017-01
(4720)

ESP SAFETY  100-0017-01

Detector de flama infrarrojo ESP Safety IPES-IR3 para la detección de incendios de vapor de combustibles. Reconocimiento de llama y señal de alarma rápidos. Envía una alarma unicamente cuando 3 diferentesondasIR detectan una llama. SalidasRS-485, 4-20 mA y de relé. LED de estado. A prueba de explosión. Diseñado para la Clase I, División 1, Grupo B, C y D. SIL3. Incluye visor de protección, soporte de montaje de acero inoxidable y hardware.

Configurar

$1,805.25 Dls
20/20MPI-R
(2940)

SPECTREX  20/20MPI-R

Detector de Flama SPECTREX Sharp Eye 20/20MPI IR3 para incendios de combustible y gasa base de hidrocarburos. Para aplicaciones en interiores. Bajo costo, alto rendimiento, alta fiabilidad y de larga distancia. Gabinete de policarbonato. 2 relés (Alarma y Fallo) o salida de 0-20mA. Compatible con RS-485 Modbus. IP55. Incluye soporte inclinable y cubierta protectora. Built-In-Test Automático y Manual (BIT). Aprobado por FM3260 y EN54-10 (Pendiente).

Configurar

$2,195.13 Dls
FSL100-IR3
(6772)

HONEYWELL  FSL100-IR3

Detector de flama Honeywell FSL100-IR3 para una detección robusta, rápida y confiable de hidrocarburos líquidos e incendios sucios en ambientes interiores / exteriores y atmósferas potencialmente explosivas. Salidas de relé y mA. Gabinete GRP. Aprobaciones EN54-10 y FM3260. IP65.

Configurar

$2,200.64 Dls
40/40C-I-6-41-AC-N-7
(6857)

SPECTREX  40/40C-I-6-41-AC-N-7

Detector de flama SPECTREX SharpEye 40/40C-I Multiespectro Quad-Sense con tecnología Triple Infrarrojo IR3. Detecta incendios de hidrocarburos a largas distancias con una inmunidad superior a falsas alarmas. 24 VDC. Incluye compatibilidad con HART, prueba incorporada automática (BIT), 3 relés para alarma, falla y salidas auxiliares y salida Modbus RS-485. Gabinete NEMA 250 6P de aluminio, libre de cobre de alta resistencia. IP66 e IP68. Aprobado por ATEX, IECEx, FM, CSA y SIL3 para Clase I Div 1 y 2.

Configurar

$4,390.25 Dls
40/40D-I-6-31-AC-N-7
(6883)

SPECTREX  40/40D-I-6-31-AC-N-7

Detector de flama SPECTREX SharpEye 40/40D-I Ultra Rápido Multiespectro Quad-Sense con tecnología IR3 Triple Infrarrojo. Detecta incendios de hidrocarburos a largas distancias con una inmunidad superior a falsas alarmas. 24 VDC. Incluye compatibilidad con HART, prueba incorporada automática (BIT), 3 relés para alarma, falla y salidas auxiliares y salida Modbus RS-485. Gabinete NEMA 250 6P de aluminio, libre de cobre de alta resistencia. IP66 e IP68. Aprobado por ATEX, IECEx, FM, CSA y SIL3 para Clase I Div 1 y 2.

Configurar

$4,829.44 Dls
Aviso de Cookies

Esta tienda en línea utiliza cookies para recordar a los usuarios, permitir el pago y recopilar información agregada que nos permite analizar los patrones de tráfico en nuestro sitio (no se almacena información personal). Para más información puedes leer nuestra Política de Privacidad.