Sensor de gas "inteligente" Detcon PI-701 con tecnología de detección de foto-ionización (PID) para Benceno 0-100ppm. Salidas de 4-20mA y Modbus RS-485. Gabinete de Ácero Inoxidable 316. Pantalla numérica incorporada. A prueba de agua, a prueba de corrosión y a prueba de vibraciones. NEMA4X. IP66. Aprobado por CSA (Clase I Div 1) y ATEX.

967-P25520-01K
Favor de solicitar precio via Email   

Conducto
Opciones

   3 Semanas  ]


Detcon Model PI-700 is a non-intrusive “Smart” sensor that use photo-ioniza- tion detector technology to monitor VOC gases over ranges from 0-10 ppm to 0-5,000 ppm. There is also a special 0-500 ppb version available. In the PI-700 sensor design, Detcon has successfully converted the sensitive laboratory style PID technology into a rugged, environmentally insensitive, and long-life industrial gas sensor. The plug-in, field replaceable detector features over-sized gold-plated connections that help prevent corrosion. The PI-700’s rugged framework includes an electro-polished 316 stainless steel housing with fully encapsulated electronics and dual layer surge protection. This inno- vative design virtually eliminates sensor failure due to water ingress, corrosion, vibration, and transient spikes. A primary feature of the Model PI-700 is embedded intuitive software that simplifies operator interface by guiding the user through routine calibration, configuration, and fault diagnostic functions using a built-in alpha/numeric display. The Model PI-700 is equipped with standard analog 4-20mA, and ModbusTM RS-485 outputs. Among its unique features is a wireless option that can be used with Detcon’s SmartWireless® product line. Additional integration options include a Remote Alarm Module (RAM), HART, and Foundation Fieldbus. Detcon’s PID sensors have a long shelf life and are supported by an industry leading warranty.

Features Failsafe User-Friendly Interface
  • LED Display (With Antiglare Cover)
  • Full Text Display Method
  • Non-intrusive Interface
  • Auto Zero/Auto Span
  • Pre-emptive Fault Diagnostics
Environmentally Bulletproof
  • Electropolished 316SS Construction
  • 100% Epoxy Encapsulated Circuitry
  • Bulletproof I/O Protection
  • Water-Proof, Corrosion-Proof, Vibration-Proof
Modular and Serviceable
  • Modular Design
  • Plug and Play Components
  • Quick Thread Release (For Sensor Replacement)
  • Integral Calibration Port
Applications
  • Pharmaceutical industry
  • Power plants
  • Chemical industry
  • Air quality
  • Refineries and petrochemical plants
  • Solvent recovery systems
  • Waste water treatment plants
  • Marine and off-shore oil wells
  • Pulp and paper industry
  • Painting and coating operations

System Specifications
Sensor TypeContinuous diffusion/adsorption
Photo Ionization Detector (PID)
Plug-in replaceable intelligent type (with replacement lamp)
Sensor Life 2 years typical
Measurement RangeGas Dependent, ranges as low as 0-10 ppm or as high as 0-5,000ppm (consult Detcon) Special Low Range 0-500 ppb
Accuracy/Repeatability±10% of reading or ±2% of range (greater of )
Response TimeT50 <30 seconds; T90 <60 seconds
OutputsLinear 4-20 mA DC
RS-485 MODBUS-RTU
Electrical ClassificationExplosion proof
CSA and US (NRTL)
Class I, Division 1, Groups B, C, D (Tamb = -20°C to +50°C)
Class I, Zone 1, Group IIB+H2
ATEX
II 2 G Ex d ib IIC T4 Gb (Tamb = -20°C to +50°C)
Ingress ProtectionNEMA 4X, IP66
Safety ApprovalsC CSA US Performance to ISA 12.13.01-2000 and CSA 22.2 #152
ATEX
CE Marking
WarrantyPlug-in cell - 1 year; Transmitter - 2 Years
Environmental Specifications
Operating Temperature Range-4°F to +122°F; -20°C to +50°C
Storage Temperature Range-4°F to +122°F; -20°C to +50°C
Operating Humidity Range0-100% RH non-condensing
Mechanical Specifications
Dimensions7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only)
11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box)
Mounting holes (J-box) 5.5"; 140mm center to center
Weight2 lbs; 0.907kg (sensor only)
6 lbs; 2.72kg (w/aluminum j-box)
9 lbs; 4.08kg (w/stainless steel j-box)
Electrical Specifications
Power Input10-30 VDC
Power ConsumptionNormal operation = 68mA (<1.7 watt)
Maximum = 85mA (2 watts)
Inrush Current1.67A @ 24V
RFI/EMI ProtectionComplies with EN61000
Analog OutputLinear 4-20mA DC (1,000 ohms max loop load @ 24VDC)
0mA: All Fault Diagnostics
2mA: In-Calibration
4-20mA: 0-100% full-scale
22mA: Over-range condition
Serial RS-485 OutputRS-485 ModbusTM RTU
Baud Rate9600 BPS (9600,N,8,1 Half Duplex)
Status Indicators4-digit LED display with gas concentration
Full-script menu prompts for AutoSpan
Set-up Options, and Fault Reporting
Faults MonitoredLoop, Input Voltage, Zero, Missing Sensor, Processor, Memory, Calibration
Cable RequirementsPower/Analog
3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG
Serial Output
2-wire twisted-pair shielded cable specifically for use with RS-485 installations
Maximum distance is 4,000 feet to last sensor
I/O ProtectionOver-voltage, Miswiring, EMI/RFI Immunity
Export Info
Fabricado enUnited States
Codigo Arancelario9027102000

 Solicitar Info/Cotizacion
 Descuento en Reventa y Vol
 Costo del Flete

Opciones B2B: #Order de Compra, uso de cuenta de envio propia y compra exenta de impuesto
Opciones de Pago: Tarjeta de Credito, Tarjeta de Credito por Telefono, PAYPAL, Transferencia, Deposito, Cheque y Orden de Pago

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESORIOS - RELACIONADOS - CONSUMIBLES :    1 Articulos encontrados.
377-P20000-01K
(6164)

DETCON  377-P20000-01K

Sensor Detcon de Foto ionizacion para PI-701-1K (0-1000ppm)



 
> BENCENO :    4 Articulos encontrados.
EX-C6H6-100L-O
(6013)

MACURCO  EX-C6H6-100L-O

Detector de gas de celda catalítica Macurco Serie Ex a prueba de explosión para la detección de Benceno (C6H6) 0-100%LEL. Incluye salida de 4-20 mA, tres relés, comunicación RS-485 y pantalla digital LCD. Gabinete de aluminio. IP66. Aprobado por FM y CSA para Clase I División 1.

Configurar

$1,555.31 Dls
1500ALD-109027/0010PP
(6907)

RC SYSTEMS  1500ALD-109027/0010PP

Detector de gas RC Systems SenSmart 1200 para Benceno (C6H6) 0-10ppm a 0-2000ppm con transmisor inteligente ST-48. Sensor PID. Salida de puente de 3 hilos. 10-30 VDC. Gabinete de aluminio o acero inoxidable. Apto para Clase 1 Div 1 (A Prueba de Explosión).

Configurar

$2,838.10 Dls
35001AL-0-9027/0010P/L0
(6895)

RC SYSTEMS  35001AL-0-9027/0010P/L0

Detector de gas RC Systems SenSmart 3500 de 3 hilos con transmisor inteligente ST-48 para Benceno (C6H6) 0-10ppm to 0-2000ppm. Sensor PID de 10.0eV. Incluye pantalla LCD gráfica, indicador LED y salida de 4-20 mA. 10-30 VDC. Gabinete de aluminio o acero inoxidable. Adecuado para Clase 1 Div 1 (A prueba de explosiones).

Configurar

$3,713.53 Dls
TXSXSLBMP-0517
(5957)

ION SCIENCE  TXSXSLBMP-0517

Detector portátil Ion Science Tiger Select para Benceno y Compuestos Aromaticos Totales (TACS) con sensor PID (hasta 20000ppm). Lampara 10.6 eV Krypton. Resistente a la humedad, rápido y preciso. IP65. Incluye batería Li-ion, puerto USB, teclado retroiluminado y registrador de datos. Aprobado por ATEX, IECEx, UL y CSA.

Configurar

$5,678.12 Dls
Aviso de Cookies

Esta tienda en línea utiliza cookies para recordar a los usuarios, permitir el pago y recopilar información agregada que nos permite analizar los patrones de tráfico en nuestro sitio (no se almacena información personal). Para más información puedes leer nuestra Política de Privacidad.