Detcon 961-ed0026-100g | Etileno | Detectores De Gas (a Prueba De Explosion) | Detectoresymedidores
Detectores de Fuga de Gases y Flama, Analizadores, Dispositivos de Alarma y Gases de Calibracion

DETCON   961-ED0026-100G

DETCON 961-ED0026-100G
  • DESCRIPCION
  • CARACTERISTICAS
  • ESPECIFICACIONES
  • LITERATURA
Detector de gas Detcon DM-100-C2H4 con sensor electroquímico para Etileno (C2H4) 0-100ppm con pantalla con alimentación de lazo (opcional). Salida de 4-100 mA. Incluye dispositivos electrónicos inteligentes, interfaz de operador no intrusiva y detector de fallas. Gabinete de acero inoxidable 316 (opcional). NPT 3/4". Intrínsecamente seguro (XP). Para Clase I, Div. 1, Grupos A, B, C y D.

961-ED0026-100G
Favor de solicitar precio via Email   

Material de terminal
Aprobación
Rango
Modulo de Relés

   3 Semanas  ]



Model DM-100 Series sensors feature intelligent electronics, non-intrusive operator interface and comprehensive fault diagnostics. The sensor is packaged in an electro-polished 316 stainless steel housing fitted with a 3⁄4 inch NPT thread. The plug-in, field replaceable sensor cell features large surface area gold-plated pins that reduce the effects of corrosion in harsh industrial environments. Signal conditioning electronics are completely encapsulated in the sensor housing adding a high level of durability to the design. The packaging is XP-intrinsically safe. This innovative design marks a return to a simple, more affordable, and durable gas detection sensor without compromising quality.

Model DM-100 sensors provide a 2-wire loop powered 4-20 mA current signal equivalent to the sensor range of detection. Upper enclosure options are aluminum and stainless steel (includes a transient protection terminal board). Additional accessories include wireless communications, a loop powered digital display. Each sensor is shipped with a splash guard with integral calibration port. Detcon’s toxic gas sensors have a long shelf life and are supported by an industry-leading warranty.

Features
  • XP-intrinsically Safe
  • Class I, Div. 1, Groups B, C & D
  • 2 Wire Loop powered
  • Field Replaceable Electrochemical Sensor
  • Non-intrusive Magnetic Interface
  • Built-in Diagnostics
  • Fully Encapsulated ITM Electronics
  • Electropolished 316SS Construction ITM
  • Quick Thread Release (for sensor replacement)
  • Integral Calibration Port
Applications
  • Oil and Gas
  • Chemical Plants
  • Food and Beverage
  • Steel Mills
  • Pulp and Paper
  • Refineries
  • Waste Water Treatment Plants
  • Utilities

System Specifications
Sensor TypeContinuous diffusion/adsorption
2-electrode electrochemical cell
Plug-in field replaceable Type
Span Drift<5% signal loss per year (in first 2 years)
OutputsLinear 4-20 mA DC
Electrical ClassificationExplosion proof
cCSAus
Class I, Division 1, Groups B, C, D (Tamb = -40°C to +50°C)
Measurement Range0-100 ppm, Other ranges available
Safety ApprovalsCCSAUS
Sensor Life/WarrantyPlug-in cell - 2 years (2 years expected life) ; Transmitter - 2 Years
Environmental Specifications
Operating Temperature Range-4 to 122oF/-20 to 50oC
Storage Temperature Range-31 to 131oF/-35 to 55oC
Operating Humidity Range0% to 99% RH non-condensing (continuous)
0%-100% RH (intermittent)
Operating Pressure RangeAtmospheric ±10%
Mechanical Specifications
Dimensions7"H x 2.2" Dia.; 178mmH x 65mm Dia. (sensor assembly only)
11"H x 6.1"W x 3.75"D; 280mmH x 155mmW x 96mmD (with junction box)
Mounting holes (J-box) 5.5" (140mm) center to center
Weight2 lbs; 0.907 kg (sensor only)
6 lbs; 2.72 kg (w/aluminum j-box)
9 lbs; 4.08 kg (w/stainless steel j-box)
Electrical Specifications
Power Input11 - 30 VDC
Power ConsumptionNormal operation = 30mA @ 24V (<0.75 watt)
Maximum = 50mA @ 24V (1.2 watts)
Inrush Current500mA @ 24V (typical)
Analog OutputLinear 4-20mA DC (1,000 ohms max loop load @ 24VDC)< br/> 0mA: All Fault Diagnostics
2mA: In-Calibration
4-20mA: 0-100% full-scale
22mA: Over-range condition
Status IndicatorsOptional 4-digit LED display with gas concentration
Full-script menu prompts for AutoSpan, Set-up Options, and Fault Reporting
Faults MonitoredLoop, Input Voltage, Missing Sensor, Zero, Processor, Memory, Calibration
Cable RequirementsPower/Analog
3-wire shielded cable
Maximum distance is 13,300 feet with 14 AWG
Serial Output
2-wire twisted-pair with ground, shielded communication cable specifically for use with RS-485 installations
Maximum distance is 4,000 feet to last sensor
Maximum distance is 4,000 feet to last sensor
I/O ProtectionOver-voltage, Miswiring
Export Info
Fabricado enUnited States
Codigo Arancelario9027102000

 Solicitar Info/Cotizacion
 Descuento en Reventa y Vol
 Costo del Flete

Opciones B2B: #Order de Compra, uso de cuenta de envio propia y compra exenta de impuesto
Opciones de Pago: Tarjeta de Credito, Tarjeta de Credito por Telefono, PAYPAL, Transferencia, Deposito, Cheque y Orden de Pago

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESORIOS - RELACIONADOS - CONSUMIBLES :    2 Articulos encontrados.
943-000006-132
(6566)

DETCON  943-000006-132

Adaptador de calibración Detcon para series FP, IR, DM, O2



 
371-444400-0100
(6200)

DETCON  371-444400-0100

Sensor Detcon de Monóxido de Carbono (CO) para DM-100-CO

> ETILENO :    5 Articulos encontrados.
6600-8075
(6275)

BACHARACH  6600-8075

Detector de gas industrial Bacharach MGS-550 con sensor semiconductor para Etileno (C2H4) 0-2,000 ppm en aplicaciones de refrigeración. Incluye 3 relés, salida analógica, salida MODBUS RS485 y pantalla de 5 dígitos. Soporta sensores remotos. Gabinete IP66. Aprobado por CE, UL y CSA.

Configurar

$797.40 Dls
EX-C2H4-100L-O
(6020)

MACURCO  EX-C2H4-100L-O

Detector de gas de celda catalítica Macurco Serie Ex a prueba de explosión para la detección de Etileno (C2H4) 0-100%LEL. Incluye salida de 4-20 mA, tres relés, comunicación RS-485 y pantalla digital LCD. Gabinete de aluminio. IP66. Aprobado por FM y CSA para Clase I División 1.

Configurar

$1,555.31 Dls
2108N4101N
(1967)

HONEYWELL  2108N4101N

Detector de Gas Honeywell Optima Plusinfrarrojo (IR) de Acero Inoxidable para Hidrocarburos (LEL). Bloque óptico de 4 canales (con compensación dual), entrada de 3 hilos de 4-20mA, Modbusopcional. Calibración para Etileno (C2H4) con barrera contra el polvo, gabinete para la intemperie y sombrilla. Célula de gasificación remota opcional.

Configurar

$2,077.10 Dls
967-12ED90-100
(6081)

DETCON  967-12ED90-100

Detector de gas electroquímico inteligente Detector de gas Detcon DM-700-C2H4 para Etileno (C2H4) 0-100 ppm con pantalla LED. Salidas de 4-20mA y Modbus RS-485. Gabinete de acero inoxidable 316. A prueba de agua, corrosión, vibraciones y explosiones. NEMA 4X. IP66. Clase I, Div. 1, Grupos B, C y D. Aprobado por CSA y ATEX.

2108N5101N
(1968)

HONEYWELL  2108N5101N

Detector de Gas Honeywell Optima Plusinfrarrojo (IR) de Acero Inoxidable para Hidrocarburos (LEL). Bloque óptico de 4 canales (con compensación dual), entrada de 3 hilos de 4-20mA, ModbusMultidrop RS485 opcional. Calibración para Etileno (C2H4). Para uso en Sistemas de muestreo remotos. Incluye gabinete de flujo y célula de gasificación remota.

Configurar

$2,612.44 Dls
Aviso de Cookies

Esta tienda en línea utiliza cookies para recordar a los usuarios, permitir el pago y recopilar información agregada que nos permite analizar los patrones de tráfico en nuestro sitio (no se almacena información personal). Para más información puedes leer nuestra Política de Privacidad.