Tyco Simplex 4098-9714 TrueAlarm Analog SSD Photoelectric Smoke Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

4098-9714   
Favor de solicitar precio via Email   

Color de la carcasa
Versión
Bases

   8 Semanas  ]



Features TrueAlarm analog sensing provides the following features
  • Digital transmission of analog sensor values using IDNet or MAPNET II two-wire communications
For use with the following Simplex products
  • 4007ES, 4010, 4010ES, 4100ES, and 4100U Series control units and 4008 Series control units with reduced feature set (refer to data sheet S4008-0001 for details)
  • 4020, 4100, and 4120 Series control units, Universal Transponders, and 2120 TrueAlarm CDTs equipped for MAPNET II operation
Photoelectric smoke sensors provide the following features
  • Sensitivity levels from 0.2% to 3.1%. See TrueAlarm sensors for more information.
General features
  • Ceiling or wall mounting
  • Listed to UL 268 7th Edition and ULC-S529
  • NEMA 1 rated. See TrueAlarm analog sensing product selection chart for more information.
  • Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted
  • Designed for EMI compatibility
  • Magnetic testing
  • Different bases support a supervised or unsupervised output relay, or a remote LED alarm indicator
Additional base reference
  • For isolator bases, refer to data sheet S4098-0025
  • For sounder bases, refer to data sheet S4098-0028
  • For photo/heat sensors, refer to data sheet S4098-0024 , single address and S4098-0033 , dual address
Digital communication of analog sensing

TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. The control unit analyses the data, determines an average value and stores it. Comparing the sensor's present value against its average value and time, determines an alarm or other abnormal condition.

Intelligent data evaluation

Monitoring each sensor's average value provides a continuously shifting reference point. A software filtering process compensates for environmental factors, such as dust and dirt, and component aging, to provide an accurate reference for evaluating new activity. This filtering reduces the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down.

Control unit selection

The control unit stores peak activity for each sensor to assist in evaluating specific locations. The host control unit determines the alarm set point for each TrueAlarm sensor, selectable as more or less sensitive as the individual application requires.

Timed/multi-stage selection

You can program the sensor alarm set points for timed automatic sensitivity selection, such as more sensitive at night, less sensitive during day. You can program the control unit to provide multi-stage operation for each sensor.

Sensor alarm and trouble LED indication

Each sensor base's LED pulses to indicate communications with the unit. If the control unit determines a sensor is in alarm, is dirty, or has some other type of trouble, the details are annunciated at the control unit and the sensor's base LED will turn on steadily. During a system alarm, the control unit will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors.

TrueAlarm sensors
  • Sealed against rear air flow entry
  • Interchangeable mounting
  • EMI/RFI shielded electronics
Smoke sensors
  • Photoelectric technology sensing
  • 360° smoke entry for optimum response
  • Built-in insect screens
4098-9714 photoelectric sensor

TrueAlarm photoelectric sensors use a stable, pulsed LED light source and a silicon photodiode receiver to deliver consistent and accurate low power smoke sensing. There are three user-selectable sensitivities for special applications for each individual sensor: 0.2%, 0.5%, and 1% for each foot. Standard sensitivity is 1.25% to 3.1% for each foot. The fire alarm control unit runs an algorithm that can vary the sensitivity for normal applications between 1.25% and 3.1% for each foot.

Note: Fixed sensitivity settings higher than 1.0% for each foot are not UL268 7th Edition compliant.

The sensor head design provides 360° smoke entry for optimum response to smoke from any direction. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow.

Specifications
Communications and sensor supervisory powerIDNet or MAPNET II communications, auto-selected, one address for each base
Communications connectionsScrew terminals for in/out wiring, 18 to 14 AWG, 0.82 mm to 2.08 mm
Remote LED alarm indicator current1 mA typical, no impact to alarm current
Remote LED alarm indicator and relay connectionsColor coded wire leads, 18 AWG, 0.82 mm
UL listed operating temperature range32°F to 100°F, 0°C to 38°C
Operating temperature range15°F to 122°F, -9°C to 50°C
Storage temperature range0°F to 140°F, -18°C to 60°C
Humidity rangeHumidity range
4098-9714 smoke sensor air velocity rating0 to 4000 ft/min, 0 to 1220 m/min
Housing colorFrost white or black

 Solicitar Info/Cotizacion
 Descuento en Reventa y Vol
 Costo del Flete

Opciones B2B: #Order de Compra, uso de cuenta de envio propia y compra exenta de impuesto
Opciones de Pago: Tarjeta de Credito, Tarjeta de Credito por Telefono, PAYPAL, Transferencia, Deposito, Cheque y Orden de Pago

Checkout with Paypal Visa MasterCard Amex Checkout with Wire Transfer Electronic Payment

> ACCESORIOS - RELACIONADOS - CONSUMIBLES :    1 Articulos encontrados.
4098-9733
(6852)

TYCO  4098-9733

Tyco Simplex 4098-9733 TrueAlarm Analog Heat Sensor with three user-selectable sensitivities. IDNet or MAPNET communications. Remote LED alarm indicator and relay connections. Ceiling or wall mounting. NEMA 1. UL and ULC Approved.

Configurar

$25.86 Dls
Aviso de Cookies

Esta tienda en línea utiliza cookies para recordar a los usuarios, permitir el pago y recopilar información agregada que nos permite analizar los patrones de tráfico en nuestro sitio (no se almacena información personal). Para más información puedes leer nuestra Política de Privacidad.