Detector de flama SPECTREX SharpEye 40/40I Triple IR. Puede detectar flamas de gasolina de 0.1m2 a 65m de distancia en menos de 5 segundos. 3 Relés de alarma (alarma, falla y auxiliar), 0-20mA (es CALonados) y compatible con ModbusRS-485.

Solicitud de Información

The 40/40I is the most durable and weather resistant flame detector currently on the market. Its new features include a heated window, to eliminate condensation and icing; HART capabilities for digital communications; lower power requirements; and a compact, lighter design.

Due to increased reliability, the 40/40 Series warranty period has been extended to 5 years and is approved to IEC 61508 Safety Integrity requirements of SIL2.

Features
  • Triple Spectrum Design - for long distance detection and high false alarm immunity
  • Sensitivity Selection - to ensure no zone crossover detection
  • Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation
  • Heated window - for operation in harsh weather conditions (snow, ice, condensation)
  • Multiple output options for maximum flexibility and compatibility
    • Relays (3) for Alarm, Fault and Auxiliary
    • 0-20mA (stepped)
    • HART Protocol for maintenance and asset management
    • RS-485, Modbus Compatible
  • High Reliability - MTBF - minimum 150,000 hours
  • Approved to Safety Integrity Level 2 (SIL2 – TUV)
  • 5-Year Warranty
  • User Programmable via HART or RS-485
  • Ex approved for Zone 1 hazardous area location
    • ATEX
    • IECEx
    • FM
    • CSA
  • 3rd party Performance Tested
    • EN54-10 (LPCB)
    • FM3260 (FM)
    • DNV Marine Approval
Applications

Offshore Oil & Gas installations Power Generationfacilities
Onshore Oil & Gas installations and pipelines Pharmaceutical Industry
Chemical plants Printing Industry
Petrochemicals plants Warehouses
Storage Tank farms Automotive Industry
Aircraft hangars Explosives & Munitions
Waste Disposal facilities  

GENERAL SPECIFICATIONS
Spectral Response Three IR Bands
Detection Range
(at highest Sensitivity Setting for 1ft2 (0.1m2) pan fire)
Fuel ft / m
n-Heptane 215 / 65
Gasoline 215 / 65
Diesel Fuel 150 / 45
JP5 150 / 45
Kerosene 150 / 45
Ethanol 95% 135 / 40
Methanol 115 / 35
IPA (Isopropyl Alcohol 135 / 40
Methane* 100 / 30
LPG* 100 / 30
Polypropylene Pellets 16 / 5
Office Paper 33/ 10
* 20" (0.5m) high, 8" (0.2m) width plume fire
Response Time Typically 5 seconds
Adjustable Time Delay Up to 30 seconds
Sensitivity Ranges 4 Sensitive ranges for 1 ft 2 (0.1m2) n-heptane pan fire from 50 ft (15m) to 215 ft (65m)
Field of View Horizontal 100º; Vertical 95º
Built-in-Test (BIT) Automatic (and Manual)
Temperature Range Operating: -67ºF to +167ºF (-55ºC to +75ºC)
Option: -67ºF to +185ºF (-55ºC to +85ºC)
Storage: -67ºF to +185ºF (-55ºC to +85ºC)
Humidity Up to 95% non-condensing (withstands up to 100% RH for short periods)
Heated Optics To eliminate condensation and icing on the window
ELECTRICAL SPECIFICATIONS
Operating Voltage 24 VDC nominal (18-32 VDC)
Power Consumption Standby: Max. 100mA (150mA with heated window)
Alarm: Max. 150mA (200mA with heated window)
Cable Entries 2 x 3/4" - 14NPT conduits or 2 x M25 x 1.5 mm ISO
Wiring 12 - 22AWG (2.5mm 2 - 0.3mm 2)
Electrical Input Protection According to MIL-STD-1275B
Electromagnetic Compatibility EMI/RFI protected to EN50130-4
Electrical Interface The detector includes twelve (12) terminals with five (5) wiring options (factory set)
OUTPUTS
Relays Alarm, Fault and Auxiliary
SPST volt-free contacts rated 5A at 30 VDC or 250 VAC.
0-20mA (stepped) Sink (source option) configuration
Fault: 0 +1mA
BIT Fault: 2mA ± 10%
Normal: 5mA ± 10%
Warning: 10mA ± 5%
Alarm: 15mA ± 5%
Resistance Loop: 100-600 Ω
HART Protocol HART communication on the 0-20mA analog current (FSK) - used for maintenance, configuration changes and asset management
RS-485 RS-485 Modbus compatible communication link that can be used in computer controlled
installations
MECHANICAL SPECIFICATIONS
Materials
Enclosure options
- Stainless Steel 316L with electro polish finish
- Heavy duty copper free aluminum (less than 1%), red epoxy enamel finish
Mounting Stainless Steel 316L with electro polish finish
Dimensions Detector 3.5" x 4.5" x 6.1" (90 x 114 x 156 mm)
Weight Detector (St.St.) 5.5 lb (2.5 kg)
Detector, aluminum 2.5 lb (1.2 kg)
Tilt mount 2.2 lb (1.0 kg)
Environmental Standards Meets MIL-STD-810C for Humidity, Salt & Fog, Vibration, Mechanical Shock, High Temp, Low Temp
Water and Dust IP66 and IP67 per EN60529, NEMA 250 6P
APPROVALS
Hazardous Area
ATEX and IECEx Ex II 2 GD,  
  Ex de IIB+H2 T5 o (-5+55 ºCºC 7 x de IIB+H2 T4 (-55ºC to + 85ºC)
  Ex tD A21 IP66/X7 T 95ºC Ex tD A21 IP66/X7 T 105ºC
FM / CSA Class I Div. 1, Groups B, C & D  
  Class II/III Div. 1, Groups E, F & G  
Performance EN54-10 (LPCB)
FM-3260 (FM)
DNV Marine Approval
Reliability IEC61508 - SIL2 (TUV)
ACCESSORIES
Fire Simulator20/20-310
Weather Protector777163
Laser Pointer
(Detector area coverage)
777166
Tilt Mount40/40-003
Air Shield777161
Export Info
Fabricado enUnited States
Codigo Arancelario90318099

  • ACCESORIOS > DETECTORES DE FLAMA SPECTREX
    789260-2 Montaje de poste (perno en U) de 2" para Detectores de flama SPECTREX SharpEye ..

  • ACCESORIOS > DETECTORES DE FLAMA SPECTREX
    794079-5 Kit RS485 USB con convertidor RS485/232. Se utiliza con el software Spectrex Host y permite al usuario conectarse a cualquier computador disponible para reconfigurar ajusteso realizar diagnósticosen todos los detectores de flama 40/40 y 20/20. ..

  • ACCESORIOS > DETECTORES DE FLAMA SPECTREX
    888810 Unidad de Diagnóstico Emerson HART Portatil con convertidor y cables (1m), software y manual incluidos. Para detectores de flama SPECTREX SharpEye ..

  • ACCESORIOS > SPECTREX DETECTORES DE FLAMA
    FS-1100 Simulador de flama SPECTREX SharpEye de largo alcance para los detectores de flama SPECTREX SharpEye Triple IR. Es la única manera de ejecutar pruebasfuncionalescompletasen susdetectoresSharpEye. Tiene certificación ATEX y Cenelec. ..

> TRIPLE IR :    8 Articulos encontrados.
20/20MPI-R
(2940)

SPECTREX  20/20MPI-R

Detector de Flama SPECTREX Sharp Eye 20/20MPI IR3 para incendios de combustible y gasa base de hidrocarburos. Para aplicaciones en interiores. Bajo costo, alto rendimiento, alta fiabilidad y de larga distancia. Gabinete de policarbonato. 2 relés (Alarma y Fallo) o salida de 0-20mA. Compatible con RS-485 Modbus. IP55. Incluye soporte inclinable y cubierta protectora. Built-In-Test Automático y Manual (BIT). Aprobado por FM3260 y EN54-10 (Pendiente).

Configurar

$1,464.61 Dls
16519-20
(6731)

FIRERAY  16519-20

Detector de llama IR3 ignífugo Fireray Talentum 16519-20 (Exd). Sensible al parpadeo y a la radiación infrarroja de baja frecuencia (1-15Hz). Salidas de relé o 4-20 mA. Aprobado por FM para Clase I Div. 1, Clase I Zona 1. Aprobado por ATEX e IECEx. IP66.

Configurar

$1,759.20 Dls
100-0017-01
(4720)

ESP SAFETY  100-0017-01

Detector de flama infrarrojo ESP Safety IPES-IR3 para la detección de incendios de vapor de combustibles. Reconocimiento de llama y señal de alarma rápidos. Envía una alarma unicamente cuando 3 diferentesondasIR detectan una llama. SalidasRS-485, 4-20 mA y de relé. LED de estado. A prueba de explosión. Diseñado para la Clase I, División 1, Grupo B, C y D. SIL3. Incluye visor de protección, soporte de montaje de acero inoxidable y hardware.

Configurar

$1,805.25 Dls
FSL100-IR3
(6772)

HONEYWELL  FSL100-IR3

Detector de flama Honeywell FSL100-IR3 para una detección robusta, rápida y confiable de hidrocarburos líquidos e incendios sucios en ambientes interiores / exteriores y atmósferas potencialmente explosivas. Salidas de relé y mA. Gabinete GRP. Aprobaciones EN54-10 y FM3260. IP65.

Configurar

$2,095.18 Dls
20/20MI-11-S-F
(2945)

SPECTREX  20/20MI-11-S-F

Detector de Flama SPECTREX SharpEye 20/20MI Mini Triple IR (IR3) para incendios de gasolina, n-heptano, diesel, jp5, queroseno, alcohol, IPA, Metanol, metano, propano, polipropileno y papel. De bajo costo, gabinete de acero inoxidable, compacto y ligero. Alta resistencia a entornoshostiles, inmune a falsas alarmasy diseñado para aplicaciones de exterior o interior. 2 relés (alarma y falla), salida analógica de 0-20mA (sumidero o fuente). Built-In-Test (BIT) automático y manual. Compatible con RS-485 Modbus. Aprobado por ATEX Ex, FM, GOST R y GOST K.

Configurar

$2,225.11 Dls
16589-20
(6730)

FIRERAY  16589-20

Detector de llama Fireray Talentum 16589-20 IR3. Sensible al parpadeo y a la radiación infrarroja de baja frecuencia (1-15Hz). Salidas de relé o 4-20 mA. Aprobado por FM para Clase I Div. 1, Clase I Zona 1. IP66.

Configurar

$2,366.40 Dls
16219-20
(6732)

FIRERAY  16219-20

Detector de llama IR3 Fireray Talentum 16219-20 ignífugo (Exd) para ambientes con altas temperaturas. Sensible al parpadeo y a la radiación infrarroja de baja frecuencia (1-15Hz). Salidas de relé o 4-20 mA. Aprobado por FM para Clase I Div. 1, Clase I Zona 1. Aprobado por ATEX e IECEx. IP66.

Configurar

$2,953.08 Dls
16549-20
(6733)

FIRERAY  16549-20

Detector de llama IR3 Fireray Talentum 16549-20 de acero inoxidable ignífugo (Exd). Sensible al parpadeo y a la radiación infrarroja de baja frecuencia (1-15Hz). Salidas de relé o 4-20 mA. Aprobado por FM para Clase I Div. 1, Clase I Zona 1. Aprobado por ATEX e IECEx. IP66.

Configurar

$3,945.60 Dls